Made up ground - Soils.

Thursday, December 9, 2010

Areas of low lying ground near the coast and around rivers close to towns and cities have been raised by tipping waste, refuse and soil from excavations. Over the years the fill will have settled and consolidated to some extent. Areas of made up ground are often used for buildings as the towns and cities expand. Because of the varied nature of the materials tipped to fill and raise ground levels and the uncertainty of the bearing capacity of the fill, conventional foundations may well be unsatisfactory as a foundation. 

An example of made up ground is the area of Westminster now known as Pimlico where the soil excavated during the construction of the London docks was transported by barge to what was low lying land that was usually flooded when high tides and heavy rainfall caused the Thames river to overflow. The raised land was subsequently heavily built on.

A uniformly stable, natural, sound foundation may well be some 3 or more metres below the surface of made up ground. To excavate to that level below the surface for conventional strip foundations would be grossly uneconomic. A solution is the use of piers on isolated pad foundations supporting reinforced concrete ground beams on which walls are raised, as illustrated in Fig. 4.

Fig.4 Pad foundation.

Subsoil drains.

Monday, December 6, 2010

Subsoil drains are used to improve the run off of surface water and the drainage of ground water to maintain the water table at some depth below the surface for the following reasons:

(1) to improve the stability of the ground
(2) to avoid surface flooding
(3) to alleviate or avoid dampness in basements
(4) to reduce humidity in the immediate vicinity of buildings.

Ground water, or land or field, drains are either open jointed or jointed, porous or perforated pipes of clayware, concrete, pitch fibre or plastic (see Volume 5). The pipes are laid in trenches to follow the fall of the ground, generally with branch drains discharging to a ditch, stream or drain.
On impervious subsoils, such as clay, it may be necessary to form a system of drains to improve the run off of surface water and drain subsoil to prevent flooding. Some of the drain systems used are natural, herring bone, grid, fan and moat or cut-off.

Resistance to ground moisture.

Up to about the middle of the nineteenth century the ground floor of most buildings was formed on compacted soil or dry fill on which was laid a surface of stone flagstones, brick or tile or a timber boarded floor nailed to battens bedded in the compacted soil or fill. In lowland areas and on poorly drained soils most of these floors were damp and cold underfoot.

A raised timber ground floor was sometimes used to provide a comparatively dry floor surface of boards, nailed to timber joists, raised above the packed soil or dry fill. To minimise the possibility of the joists being affected by rising damp it was usual to ventilate the space below the raised floor. The inflow of cold outside air for ventilation tended to make the floor cold underfoot.

Trial Pits - make an examination of the subsoil on a building site.

Friday, December 3, 2010

To make an examination of the subsoil on a building site, trial pits or boreholes are excavated. Trial pits are usually excavated by machine or hand to depth of 2 to 4 m and at least the anticipated depth of the foundations. The nature of the subsoil is determined by examination of the sides of the excavations. Boreholes are drilled by hand auger or by machine to withdraw samples of soil for examination. Details of the subsoil should include soil type, consistency or strength, soil structure, moisture conditions and the presence of roots at all depths. From the nature of the subsoil the bearing capacity, seasonal volume changes and other possible ground movements are assumed. To determine the nature of the subsoil below the foundation level it is either necessary to excavate trial pits some depth below the foundation or to bore in the base of the trial hole to withdraw samples. Whichever system is adopted will depend on economy and the nature of the subsoil. Trial pits or boreholes should be sufficient in number to determine the nature of the subsoil over and around the site of the building and should be at most say 30 m apart.

Ground movements that may cause settlement are:

(1) compression of the soil by the load of the building
(2) seasonal volume changes in the soil
(3) mass movement in unstable areas such as made up ground and mining areas where there may be considerable settlement
(4) ground made unstable by adjacent excavations or by dewatering, for example, due to an adjacent road cutting.
It is to anticipate and accommodate these movements that site investigation and exploration is carried out.

Site visit - Soils.

A visit to the site and its surroundings should always be made to record everything relevant from a careful examination of the nature of the subsoil, vegetation, evidence of marshy ground, signs of ground water and flooding, irregularities in topography, ground erosion and ditches and flat ground near streams and rivers where there may be soft alluvial soil. A record should be made of the foundations of old buildings on the site and cracks and other signs of movement in adjacent buildings as evidence of ground movement.

Site Investigation - Select a foundation from tables, or to design a foundation.

To select a foundation from tables, or to design a foundation, it is necessary to calculate the loads on the foundation and determine the nature of the subsoil, its bearing capacity, its likely behaviour under seasonal and ground water level changes and the possibility of ground movement. Where the nature of the subsoil is known from geological surveys, adjacent building work or trial pits or borings and the loads on foundations are small, as for single domestic buildings, it is generally sufficient to excavate for foundations and confirm, from the exposed subsoil in the trenches, that the soil is as anticipated.

Under strip and pad foundations there is a significant pressure on the subsoil below the foundations to a depth and breadth of about one-and-a-half-times the width of the foundation. If there were, in this area below the foundation, a soil with a bearing capacity less than that below the foundation, then appreciable settlement of the foundation might occur and damage the building. It is important, therefore, to know or ascertain the nature of the subsoil both at the level of the foundation and for some depth below.

Where the nature of the subsoil is uncertain or there is a possibility of ground movement or a need to confirm information on subsoils, it is wise to explore the subsoil over the whole of the site of the building.

As a first step it is usual to collect information on soil and subsoil conditions from the County and Local Authority, whose local knowledge from maps, geological surveys, aerial photography and works for buildings and services adjacent to the site may in itself give an adequate guide to subsoil conditions. In addition geological maps from the British Geological Survey, information from local geological societies, Ordnance Survey maps, mining and river and coastal information may be useful.

Unstable ground - Soils.

There are some extensive areas of ground in this country where mining and excavations for coal and excavations for taking out chalk for use as a fertiliser and making lime and others for extracting sand and gravel may have made the ground unstable. The surface of the ground under deep and shallow excavations below the surface may well be subject to periodic, unpredictable subsidence.

Where it is known that ground may be unstable and there is no ready means of predicting the possibility of mass movement of the subsoil and it is expedient to build, a solution is to use some form of reinforced concrete raft under the whole of’ the buildings, as illustrated in Fig. 5.

The concrete raft, which is cast on or just below the surface, is designed to spread the load of the building over the whole of the underside of the raft so that in a sense the raft floats on the surface.

Fig. 5 Raft foundation.

Frost Heave - Soils.

Thursday, December 2, 2010

Where the water table is high, that is near the surface, soils, such as silts, chalk, fine gritty sands and some lean clays, near the surface may expand when frozen. This expansion, or frost heave, is due to crystals of ice forming and expanding in the soil and so causing frost heave. In this country, ground water near the surface rarely freezes at depths of more than 0.5 m, but in exposed positions on open ground during frost it may freeze up to a depth of I m. Even in exposed positions during severe frost it is most unlikely that ground water under and adjacent to the foundations of heated buildings will freeze because of the heat stored in the ground under and around the building. There is, therefore, no need to consider the possibility of ground movement due to frost heave under and around heated buildings.

For unheated buildings and heated buildings with insulated ground floors, a foundation depth of 450 mm is generally sufficient against the possibility of damage by ground movement due to frost heave.

Volume Change - Soils.

Firm, compact shrinkable clays suffer appreciable vertical and horizontal shrinkage on drying and expansion on wetting due to seasonal changes. Seasonal volume changes under grass extend to about 1 m below the surface in Great Britain and up to depths of4m or more below large trees.

The extent of volume changes, particularly in firm clay soils, depends on seasonal variations and the proximity of trees and shrubs. The greater the seasonable variation, the greater the volume change. The more vigorous the growth of shrubs and trees in firm clay soils, the greater the depth below surface the volume change will occur.

As a rough guide it is recommended that buildings on shallow foundations should not be closer to single trees than the height of the tree at maturity, and one-and-a-half times the height at maturity of groups of trees, to reduce the risk of damage to buildings by seasonal volume changes in clay subsoils.

When shrubs and trees are removed to clear a site for building on firm clay subsoils there will, for some years after the clearance, be ground recovery as the clay gradually recovers moisture previously withdrawn by the shrubs and trees. This gradual recovery of water by the clay and consequent expansion may take several years. The depth at which the recovery and expansion is appreciable will be roughly proportional to the height of the trees and shrubs removed, and the design and depth of foundations of buildings must allow for this gradual expansion to limit damage by differential settlement. Similarly, if vigorous shrub or tree growth is stopped by removal, or started by planting, near to a building on firm clay subsoil with foundations at a shallow depth, it is most likely that gradual expansion or contraction of the soil will cause damage to the building by differential movement.

At the recommended depth of at least 0.9 m it is not generally economic to use the traditional strip foundation and hence the narrow strip or trench fill foundation (Fig. 9) has been used. A narrow trench 400 mm wide is excavated by machine and filled with concrete to just below the surface. If the concrete is placed immediately after the excavation there is no need to support the sides of the trench in stiff clays, the sides of the trench will not be washed away by rain and the exposed clay will not suffer volume change.

The foundations of buildings sited adjacent to past, present or future deep-rooted vegetation can be affected at a considerable depth below the surface by the gain or removal of ground moisture and consequent expansion or shrinkage. Appreciable expansion, following the removal of deep-rooted vegetation, may continue for some years as the subsoil gains moisture. Significant seasonal volume change, due to deep-rooted vegetation, will be pronounced during periods of drought and heavy continuous rainfall.


The vigorous growth of newly planted deep-rooted vegetation adjacent to buildings may cause continuous shrinkage in clay soils for some years. The most economical and effective foundation for low rise buildings on shrinkable clays close to deep-rooted vegetation is a system of short-bored piles and ground beams (Fig. 3). 

The piles should be taken down to a depth below which vegetation roots will not cause significant volume changes in the subsoil. Single deep- rooted vegetation such as shrubs and trees as close as their mature height to buildings, and groups of shrubs and trees one-and-a-half times their mature height to buildings, can affect foundations on shrinkable clay subsoils.

Many beds of clay consist of combinations of clay with sand or silt in various proportions. The mix of sand or silt to clay will affect the behaviour of these soils as a foundation. in general where the proportion of sand or silt to clay is appreciable the less dense the soil will be. Because of variations in the proportion of clay to sand or silt and the general loose or soft nature of the soil it is practice to assume that their bearing capacity is less than that of clay. 

Fig. 3 Pile Foundation.

Fine Grained Cohesive Soils.

Fine grained cohesive soils, such as clays, are a natural deposit of the finest siliceous and aluminous products of rock weathering. Clay is smooth and greasy to the touch, shows high plasticity, dries slowly and shrinks appreciably on drying. Under the pressure of the load on foundations clay soils are very gradually compressed by the expulsion of water through the very many fine capillary paths, so that buildings settle gradually during building work and this settlement may continue for some years after the building is completed.

The initial and subsequent small settlement by compression during and after building on clay subsoils will generally be uniform under most small buildings, such as houses, to the extent that no damage is caused to the structure and its connected services.

Sand.

Sand is a natural sediment of granular, mainly siliceous, products of rock weathering. Particles are smaller than 2 mm, are visible to the naked eye and the smallest size is 0.06 mm. Sand is gritty, has no real plasticity and can be easily powdered by hand when dry.

Dense, compact gravel and sand requires a pick to excavate for foundation trenches. A test of the suitability of these soils as a foundation is that it is difficult to drive a 5 mm wooden peg more than some 150 mm into compact gravel or sand.

As a foundation for small buildings, such as a house, it is sufficient to spread and level a continuous strip of concrete in the excavated trenches as a level base for load bearing walls.

Figure 2 is a diagram illustrating a strip foundation, The continuous strip of concrete is spread in the trenches excavated down to an undisturbed level of compact soil. The strip of concrete may well need to be no wider than the thickness of the wall. In practice the concrete strip will generally be wider than the thickness of the wall for the convenience of covering the whole width of the trench and to provide a wide enough level base for bricklaying below ground. A continuous strip foundation of concrete is the most economic form of foundation for small buildings on compact soils. 

Fig. 2 Strip foundation.

Soils: Top Soil, Subsoil, Coarse grained non-cohesive soils.

Soil is the general term for the upper layer of the earth’s surface which consists of various combinations of particles of disintegrated rock such as gravel, sand or clay with some organic remains of decayed vegetation generally close to the surface.

Top Soil.

The surface layer of most of the low lying land in this country, which is most suited to building, consists of a mixture of loosely compacted particles of sand, clay and an accumulation of decaying vegetation. This layer of top soil, which is about 100 to 300 mm deep, is sometimes referred to as vegetable top soil. It is loosely compacted, supports growing plant life and is unsatisfactory as a foundation. It should be stripped from the site of buildings because of its poor bearing strengths and its ability to retain moisture and support vegetation which might adversely affect the health of occupants of buildings.

Subsoil.

Subsoil is the general term for soil below the top soil.

It is unusual for a subsoil to consist of gravel, sand or clay by itself. The majority of subsoils are mixes of various soils. Gravel, sand and clay may be combined in a variety of proportions. To make a broad assumption of the behaviour of a particular soil under the load on foundations it is convenient to group soils such as gravel, sand and clay by reference to the size and nature of the particles.

The three broad groups are coarse grained non-cohesive, fine grained cohesive and organic. The nature and behaviour under the load on foundations of the soils in each group are similar. 

Coarse grained non-cohesive soils.

Soils which are composed mainly of, or combinations of, sand and gravel consist of largely siliceous, unaltered products of rock weathering. They have no plasticity and tend to lack cohesion, especially when dry. Under pressure of the loads on foundations the soils in this group compress and consolidate rapidly by some rearrangement of the coarse particles and the expulsion of water. 

A foundation on coarse grained non-cohesive soils settles rapidly by consolidation of the soil, as the building is erected, so that there is no further settlement once the building is completed.

 
 
 